CCSD3ZF0000100000001NJPL3IF0PDS200000001 = SFDU_LABEL                         
/*               File Format and Length                               */      
RECORD_TYPE                     = FIXED_LENGTH                                
RECORD_BYTES                    = 4                                           
FILE_RECORDS                    = 800                                         
DATA_SET_ID                     = "IHW-C-SPEC-3-EDR-HALLEY-V1.0"              
OBSERVATION_ID                  = "701449"                                    
TARGET_NAME                     = "HALLEY"                                    
OBSERVATION_TIME                = 1985-10-16T11:23:15.074Z                    
START_TIME                      = 1985-10-16T11:18:15.074Z                    
/*               Record Pointer to Object                             */      
^SPECTRUM                       = "SPEC0245.DAT"                              
/*               Description of Object in File                        */      
OBJECT                          = SPECTRUM                                    
 ROWS                           = 800                                         
 COLUMNS                        = 1                                           
 INTERCHANGE_FORMAT             = BINARY                                      
 NOTE                           = "SPECTROSCOPY, 1-D SPECTRUM"                
 OBJECT                         = COLUMN                                      
  COLUMN_NAME                   = FLUX_PER_FREQUENCY                          
  DATA_TYPE                     = MSB_INTEGER                                 
  START_BYTE                    = 1                                           
  BYTES                         = 4                                           
  OFFSET                        = 7.069190E-26                                
  SCALING_FACTOR                = 3.291850E-35                                
  DERIVED_MAXIMUM               = 1.413840E-25                                
  DERIVED_MINIMUM               = -3.276430E-32                               
  SAMPLING_PARAMETER_NAME       = "WAVELENGTH"                                
  SAMPLING_PARAMETER_UNIT       = ANGSTROM                                    
  MINIMUM_SAMPLING_PARAMETER    = 5719.72                                     
  SAMPLING_PARAMETER_INTERVAL   = 2.693                                       
 END_OBJECT                     = COLUMN                                      
END_OBJECT                      = SPECTRUM                                    
END