PDS_VERSION = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 1997-01-20 NOTE = "MGS RST Instrument Health Report HEA7020A.TXT" END_OBJECT = TEXT END Engineering Data ================ Engineering Data Statistical Summary from CSV2STAT: First SCET: 1997-01-19T04:47:24.903 Last SCET: 1997-01-19T23:59:59.901 CHANNL DN-LO DN-MD DN-HI EU-LO EU-MEDIAN EU-HIGH EU AVG/STDEV RECDS ------ ----- ----- ----- --------- --------- --------- --------- -------- ----- L-0200 203 204 205 4.06E+00 4.08E+00 4.10E+00 4.08E+00/7.35E-05 6598 L-0201 126 128 129 2.52E+00 2.56E+00 2.58E+00 2.56E+00/8.60E-05 6598 T-0315 152 154 156 1.71E+01 1.77E+01 1.83E+01 1.78E+01/5.74E-03 1647 USO regulated voltage (L-0200) and USO oven voltage (L-0201) remain constant. USO temperature (T-0315) is down another 0.6C from the last report 48 hrs ago. There was no MOT/TWTA/Antenna swapping on 1997/019. But there was an increase in several temperatures at about 13 h, suggesting a maneuver. There is nothing in c0404.00.soe that explains these changes. Open Loop Data ============== Data Collection --------------- No new data Closed Loop Data ================ No new data