PDS_VERSION = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 1997-06-25 NOTE = "MGS RST Instrument Health Report HEA7176A.TXT" END_OBJECT = TEXT END This report is being submitted by Joe Twicken. Dick Simpson is out of the office until next week. Engineering Data Statistical Summary from CSV2STAT: First SCET: 1997-06-24T00:00:00.125 Last SCET: 1997-06-24T23:59:59.620 CHANNL CHANNEL TITLE DN-LO DN-HI EU-LO EU-HI EU-AVG/STDEV RECDS ------ ------------- ----- ----- --------- --------- ---------/-------- ----- L-0034 MOT1_RANGING 0 0 18484 L-0036 MOT1_TLM_MOD 0 0 18484 L-0037 MOT1_USO_ENA 0 0 18484 L-0044 MOT2_RANGING 1 1 18484 L-0046 MOT2_TLM_MOD 1 1 18484 L-0047 MOT2_USO_ENA 1 1 18484 L-0053 RF_SW_OSC 1 1 18484 L-0060 TWTA1_FILMNT 0 0 18484 L-0061 TWTA1_HV 0 0 18484 L-0070 TWTA2_FILMNT 1 1 18484 L-0071 TWTA2_HV 0 0 18484 L-0080 USO_PWR 0 0 18484 L-0090 KaBLE_STAT 1 1 18484 L-0091 KaBLE_ENABLE 0 0 18484 L-0111 MOT1_RCV_AGC 199 255 -1.53E+02 -1.36E+02 -1.50E+02/4.18E-02 9242 L-0121 MOT2_RCV_AGC 149 255 -1.53E+02 -1.22E+02 -1.33E+02/5.41E-02 9242 L-0131 TWTA1_HLX_I 0 1 -3.84E-02 -1.85E-02 -3.83E-02/1.07E-05 9242 L-0132 TWTA1_ANOD_V 0 2 -1.00E+03 -1.00E+03 -1.00E+03/2.76E-03 9242 L-0141 TWTA2_HLX_I 39 43 7.25E-01 8.05E-01 7.67E-01/1.42E-04 9242 L-0142 TWTA2_ANOD_V 60 64 -8.68E+02 -8.60E+02 -8.63E+02/1.39E-02 9242 L-0200 USO_REG_V 203 205 4.06E+00 4.10E+00 4.08E+00/8.43E-05 9242 L-0201 USO_OVEN_V 123 126 2.46E+00 2.52E+00 2.50E+00/6.18E-05 9242 T-0302 EPC1_T 118 124 2.59E+01 2.85E+01 2.75E+01/9.35E-03 2312 T-0303 EPC2_T 106 111 3.16E+01 3.37E+01 3.28E+01/8.41E-03 2312 T-0310 RF_ISOLTR1_T 177 182 2.75E+01 2.93E+01 2.85E+01/2.99E-03 9242 T-0311 RF_ISOLTR2_T 168 174 3.03E+01 3.24E+01 3.14E+01/3.54E-03 9242 T-0312 TWT1_T 175 181 2.79E+01 3.00E+01 2.88E+01/7.95E-03 2312 T-0313 TWT2_T 161 167 3.28E+01 3.49E+01 3.38E+01/9.19E-03 2312 T-0315 USO_T 171 175 1.15E+01 1.27E+01 1.22E+01/3.54E-03 2312 T-0316 KA_AMP_T 146 153 3.78E+01 4.05E+01 3.92E+01/6.58E-03 4622 L-0200 is nominal at 4.08 volts. L-0201 is nominal at 2.50 volts. T-0315 remains nominal between 11.5 and 12.7 C. Open Loop Data ============== Data Collection --------------- The USO Test #11 ODS was retransmitted at the end of last week. We requested the retransmission because there were 10 missing records in the ODS. During the test, the DSP failed and had to be rebooted; 40 minutes of data were lost as a result (in addition to the missing ODS records). For some unknown reason, the ODS data which were acquired before the DSP failure were not retransmitted. The data which were retransmitted covered the time period 97/162-03:12:30 to 97/162-04:00:00. I was unable to successfully query for the ODS. As with the original ODS, the data were only available from a query server to which we at Stanford do not have access. Trish Priest was able to query for the ODS at JPL yesterday and I obtained the file from her by ftp. There were not any missing records in the retransmitted data. I will include an Allan deviation analysis of the retransmitted USO Test #11 data in the RST instrument health report tomorrow. Anomalies --------- USO Test #11 retransmission only included the open-loop data acquired after the DSP was restarted at 97/162-03:12:30. The data were not available from the usual NERT query server and I was unable to obtain them in the manner that data will have to be transfered during mapping. We have already submitted an ISA regarding this problem. Closed Loop Data ================ Data Collection --------------- We have obtained the following files from OSCAR and EPIC: Original File Name Name on SOPC ------------------------------ ------------ ATDF: ODF: 97175C176.DAT;1 7175176A.ODF IONCAL: TROPCAL: WEATHER: UTPM: EOP: 970624-eop.long 20207210.EOP 970624-eop.short 62107210.EOP