PDS_VERSION = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 1997-07-11 NOTE = "MGS RST Instrument Health Report HEA7192A.TXT" END_OBJECT = TEXT END Engineering Data ================ Engineering Data Statistical Summary from CSV2STAT: First SCET: 1997-07-10T00:00:00.487 Last SCET: 1997-07-10T23:59:59.982 CHANNL CHANNEL TITLE DN-LO DN-HI EU-LO EU-HI EU-AVG/STDEV RECDS ------ ------------- ----- ----- --------- --------- ---------/-------- ----- L-0034 MOT1_RANGING 0 0 25880 L-0036 MOT1_TLM_MOD 0 0 25880 L-0037 MOT1_USO_ENA 0 0 25880 L-0044 MOT2_RANGING 1 1 25880 L-0046 MOT2_TLM_MOD 1 1 25880 L-0047 MOT2_USO_ENA 1 1 25880 L-0053 RF_SW_OSC 1 1 25880 L-0060 TWTA1_FILMNT 0 0 25880 L-0061 TWTA1_HV 0 0 25880 L-0070 TWTA2_FILMNT 1 1 25880 L-0071 TWTA2_HV 0 0 25880 L-0080 USO_PWR 0 0 25880 L-0090 KaBLE_STAT 1 1 25880 L-0091 KaBLE_ENABLE 0 0 25880 L-0111 MOT1_RCV_AGC 200 255 -1.53E+02 -1.37E+02 -1.45E+02/4.58E-02 12940 L-0121 MOT2_RCV_AGC 150 255 -1.53E+02 -1.23E+02 -1.35E+02/9.18E-02 12940 L-0131 TWTA1_HLX_I 0 1 -3.84E-02 -1.85E-02 -3.83E-02/7.50E-06 12940 L-0132 TWTA1_ANOD_V 0 2 -1.00E+03 -1.00E+03 -1.00E+03/2.62E-03 12940 L-0141 TWTA2_HLX_I 39 43 7.25E-01 8.05E-01 7.65E-01/1.23E-04 12940 L-0142 TWTA2_ANOD_V 60 65 -8.68E+02 -8.58E+02 -8.63E+02/1.17E-02 12940 L-0200 USO_REG_V 202 205 4.04E+00 4.10E+00 4.08E+00/7.22E-05 12940 L-0201 USO_OVEN_V 123 126 2.46E+00 2.52E+00 2.50E+00/6.27E-05 12940 T-0302 EPC1_T 119 125 2.55E+01 2.81E+01 2.69E+01/7.83E-03 3234 T-0303 EPC2_T 107 112 3.11E+01 3.33E+01 3.23E+01/7.43E-03 3234 T-0310 RF_ISOLTR1_T 178 183 2.72E+01 2.89E+01 2.80E+01/2.80E-03 12940 T-0311 RF_ISOLTR2_T 169 175 3.00E+01 3.21E+01 3.10E+01/2.94E-03 12940 T-0312 TWT1_T 177 183 2.72E+01 2.93E+01 2.84E+01/7.04E-03 3234 T-0313 TWT2_T 162 169 3.21E+01 3.45E+01 3.33E+01/7.63E-03 3234 T-0315 USO_T 172 175 1.15E+01 1.24E+01 1.20E+01/3.17E-03 3234 T-0316 KA_AMP_T 147 156 3.67E+01 4.01E+01 3.85E+01/6.78E-03 6468 L-0200, L-0201, and T-0315 are nominal. Open Loop Data ============== Data Collection --------------- No new data. Analyses -------- Although not included in yesterday's report, Joe Twicken has also processed the 75 seconds of data recorded while the TWTA was warming up prior to the fourth simulated occultation in RS ORT #1. The plots do not have resolution suitable for detailed study, but there is clearly a frequency transient during the first few seconds of warm-up on the order of Hertz to perhaps tens of Hertz. But within 30 seconds of power-ON, frequency estimates are within the normal statistical range. On time scales of seconds, there was no detectable amplitude transient. The 75 seconds of warm-up allowed during the ORTs should be more than adequate for achieving stability. Closed Loop Data ================ Data Collection --------------- We have obtained the following files from OSCAR and EPIC: Original File Name Name on SOPC ------------------------------ ------------ ATDF: ODF: 97191C192.DAT;1 7191192A.ODF IONCAL: TROPCAL: WEATHER: UTPM: EOP: Ancillary Data ============== Data Collection --------------- We have obtained the following files from the CDB: Original File Name Name on SOPC ------------------------------ ------------ SPK: spk_c_970321-970903 7080246A.SPK