NAME = RAD COLUMNS = 10 ROW_BYTES = 28 INTERCHANGE_FORMAT = BINARY PRIMARY_KEY = ( "SPACECRAFT_CLOCK_START_COUNT", "DETECTOR_NUMBER" ) DESCRIPTION = " The RAD table contains the raw and calibrated observed radiances. For each observation there can be up to 6 RAD records, one for each active spectrometer detector. If the Temporal Integration Count (OBS Table, TEMPORAL_AVERAGE_COUNT) is greater than 1, then the data represent the average of the measurements from that many scans. The instrument can apply a programmable spectral mask to the raw data causing neighboring channels to be averaged; however, this feature is used only when downlink bandwidth is limited. When spectrally masked data are received, the averaged-out channels are replaced with the averaged value to expand the spectra back to its original size. The spectral-mask that was used to perform the averaging is kept in this table. The raw spectra are compressed for downlink. The original bit-packed compression header, containing the size of the compressed data and the compression mode used, is kept in this table in order to be used to evaluate the performance of the compressor." OBJECT = COLUMN NAME = SPACECRAFT_CLOCK_START_COUNT DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 4 ALIAS_NAME = sclk_time DESCRIPTION = "The value of the spacecraft clock at the beginning of the observation" END_OBJECT = COLUMN OBJECT = COLUMN NAME = DETECTOR_NUMBER DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 1 ALIAS_NAME = detector DESCRIPTION = "The number of the spectrometer detector that made the observation. Detectors are numbered from 1 to 6" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SPECTRAL_MASK DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 6 BYTES = 1 ALIAS_NAME = spectral_mask DESCRIPTION = "ID number of spectral mask applied. See ancillary Masks table" END_OBJECT = COLUMN OBJECT = COLUMN NAME = COMPRESSION_MODE DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 7 BYTES = 2 ALIAS_NAME = cmode DESCRIPTION = "16-bit compression header of original data containing the size and compression mode of the original compressed data. See TES Users Guide." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RAW_RADIANCE DATA_TYPE = MSB_INTEGER START_BYTE = 9 BYTES = 4 VAR_DATA_TYPE = MSB_INTEGER VAR_ITEM_BYTES = 2 VAR_RECORD_TYPE = Q15 ALIAS_NAME = raw_rad DESCRIPTION = "Raw spectral radiance" UNIT = "transformed volts" END_OBJECT = COLUMN OBJECT = COLUMN NAME = CALIBRATED_RADIANCE DATA_TYPE = MSB_INTEGER START_BYTE = 13 BYTES = 4 VAR_DATA_TYPE = MSB_INTEGER VAR_ITEM_BYTES = 2 VAR_RECORD_TYPE = Q15 ALIAS_NAME = cal_rad DESCRIPTION = "Calibrated spectral radiance" UNIT = "watts cm-2 steradian-1 wavenumber-1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = DETECTOR_TEMPERATURE DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 17 BYTES = 2 ALIAS_NAME = tdet DESCRIPTION = "Derived temperature of the detector, used to remove instrument radiance in calibration algorithm" UNIT = "K" SCALING_FACTOR = 0.01 END_OBJECT = COLUMN OBJECT = COLUMN NAME = TARGET_TEMPERATURE DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 19 BYTES = 2 ALIAS_NAME = target_temp DESCRIPTION = "Derived temperature of the observed target" UNIT = "K" SCALING_FACTOR = 0.01 END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADIANCE_CALIBRATION_ID DATA_TYPE = CHARACTER START_BYTE = 21 BYTES = 4 ALIAS_NAME = version_id DESCRIPTION = "Calibration algorithm version id for spectral data." END_OBJECT = COLUMN OBJECT = COLUMN NAME = QUALITY DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 25 BYTES = 4 ALIAS_NAME = quality DESCRIPTION = "Quality word, bits TBD." END_OBJECT = COLUMN