PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT NOTE = "Comments on MGS Thermal Emission Spectrometer (TES) Archive Volumes (ERRATA.TXT)" PUBLICATION_DATE = 1999-08-24 END_OBJECT = TEXT END COMMENTS ON MGS TES ARCHIVE VOLUMES MGST_0021 THROUGH MGST_0010 This document contains comments and errata concerning the MGS Thermal Emission Spectrometer Archive Volumes MGST_0021 through MGST_0010. 1. Nonstandard file names in SOFTWARE directory A few files in the SOFTWARE/SRC directory do not conform to the ISO 9660 8.3 filename standard. Specifically, the file MAKEFILE does not have an extension, and the files IO_LABLIB3.C and IO_LABLIB3.H have more than 8 characters in the filename. 2. Nonstandard file sizes in DATA/MARS/ directory on Volumes MGST_0001 through MGST_0008 The following TES Standard Data Products contain only one orbit of size 130 to 250 Mb; this is significantly larger than the documented 100 Mb per product (see DOCUMENT/ARCHSIS.ASC section 3.2): MGST_0001: TES000101, TES000102 MGST_0002: TES000201, TES000202 MGST_0003: TES000301, TES000302 MGST_0004: TES000401, TES000402, TES000403 MGST_0005: TES000501, TES000502, TES000503 MGST_0006: TES000601, TES000602 MGST_0007: TES000701, TES000702, TES000703 MGST_0008: TES000801, TES000802, TES000803 3. Errors in DOCUMENT/PROCESS.ASC and PROCESS.PDF on Volumes MGST_0061 through MGST_0010 While converting the document text files PROCESS.ASC and PROCESS.PDF, superscript and subscript formats were lost and could potentially lead to confusion. The documents should be read with the understanding that 10-6 indicates 10, or another value, raised to the -6 power; cm-1 indicates cm, or another unit, raised to the -1 power; d2?/d?2 indicates the second derivative is taken; the equation on line 476 should read dIRF/dT = 3*af*(detector_temp)^2 + 2*bf*detector_temp + cf; and the equation on line 493 should read Corr_IRF = IRF + dIRF/dT *deltaT + d2IRF/dT2 * deltaT^2 / 2! . 4. Errors in DOCUMENT directory on Volumes MGST_0061 through MGST_0044 On Volumes MGST_0061 and MGST_0041 through MGST_0044, the files SDPSIS.PDF and SDPSIS.ASC, section 3.1 lists a sample label with the nested PDS object "PRIMARY_KEYS". It should be "PRIMARY_KEY". 5. Nonstandard keyword in DATA/MARS/*.FMT files and associated software On Volume MGST_0021, the DATA/MARS/*.FMT files contain the keyword PRIMARY_KEYS; on subsequent volumes, this keyword was modified to PRIMARY_KEY and the associated software was adjusted to accommodate the change. Therefore, the software on MGST_0021 is incompatible with the DATA/MARS/*.FMT files on any volume produced later. The revised software and corresponding *.FMT files can be used to manipulate the MGST_0021 data located in the DATA/MARS/*.TAB or DATA/MARS/*.VAR files. 6. Errors in CATALOG directory on Volume MGST_0021 On Volume MGST_0021, some files in the CATALOG directory do not conform to the PDS standard for names of catalog object files. Specifically, HOST.CAT should be INSTHOST.CAT, TESINST.CAT should be INST.CAT, TSDRDS.CAT should be DATASET.CAT, PERSONEL.CAT should be PERSON.CAT, and REFS.CAT should be REF.CAT. Also on Volume MGST_0021, the file TARGET.CAT is missing from the CATALOG directory. Also on Volume MGST_0021, the file REFS.CAT is missing the following reference: OBJECT = REFERENCE REFERENCE_KEY_ID = "ASMAR&RENZETTI1993" REFERENCE_DESC = "Asmar, S.W., and N.A. Renzetti, The Deep Space Network as an Instrument for Radio Science Research, Jet Propulsion Laboratory Publication 80-93, Rev. 1, 15 April 1993." END_OBJECT = REFERENCE 7. Errors in DOCUMENT directory on Volume MGST_0021 On Volume MGST_0021, the files SDPSIS.PDF and SDPSIS.ASC, section 3.1 lists a sample label with the statement TABLE = "xxx". It should be ^TABLE = "xxx". On Volume MGST_0021, the PDS label files ARCHSIS.LBL, PROCESS.LBL, and SDPSIS.LBL in the DOCUMENT directory all have the keyword DESCRIPTION. It should be called NOTE to conform to PDS standards for text object labels. On Volume MGST_0021, the files ARCHSIS.ASC, PROCESS.ASC, and SDPSIS.ASC in the DOCUMENT directory are not PDS-compliant because they contain TAB characters and have some lines longer than 80 characters.