PDS_VERSION_ID = PDS3 RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 203 FILE_RECORDS = 137 DESCRIPTION = "This table contains science data directed to RAM during the freefall and entry sub-phases of the EDL phase of the Mars Pathfinder mission. The data is from the MET wind, pressure, temperature, and associated housekeeping sensors." ^TABLE = "RF_MET_S.TAB" DATA_SET_ID = "MPFL-M-ASIMET-2/3-EDR/RDR-EDL-V1.0" MISSION_NAME = "MARS PATHFINDER" INSTRUMENT_HOST_NAME = "MARS PATHFINDER LANDER" INSTRUMENT_NAME = "ATMOSPHERIC STRUCTURE INSTRUMENT / METEOROLOGY PACKAGE" PRODUCT_NAME = "RAM FREEFALL/ENTRY MET SCIENCE DATA" PRODUCT_ID = "RAM-FE-MET-SCIDAT" TARGET_NAME = "MARS" SPACECRAFT_CLOCK_START_COUNT = "1246725418.000" SPACECRAFT_CLOCK_STOP_COUNT = "1246726504.000" START_TIME = 1997-07-04T16:36:50.172Z STOP_TIME = 1997-07-04T16:54:56.175Z PRODUCT_CREATION_TIME = 1998-09-08T22:40:00.000Z OBJECT = TABLE INTERCHANGE_FORMAT = ASCII ROW_BYTES = 203 ROWS = 137 COLUMNS = 26 OBJECT = COLUMN NAME = "SPACECRAFT_CLOCK_START_COUNT" DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 16 FORMAT = "F16.5" UNIT = SECOND DESCRIPTION = "Spacecraft clock count in decimal seconds. Note that this is a non-standard format for the spacecraft clock which may not be used as input to NAIF-provided time conversion software tools. It has been converted to a decimal format from the original format in which the fractional portion of the number represented the number of 256ths of a second. Please see the SCLKTIME.ASC file on the MPAM_0001 CD for more information." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ELAPSED_TIME" DATA_TYPE = ASCII_REAL START_BYTE = 18 BYTES = 11 FORMAT = "F11.5" UNIT = SECOND DESCRIPTION = "Elapsed time in seconds. At time = 0, the spacecraft clock count was 1246725418.00000, and the UTC time was 1997-07-04T16:36:50.172Z." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_CURRENT" DATA_TYPE = ASCII_REAL START_BYTE = 30 BYTES = 7 FORMAT = "F7.3" UNIT = MILLIAMP DESCRIPTION = "Wind sensor current, measured in milliamps." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_MID_MAST_THERMOCOUPLE" DATA_TYPE = ASCII_REAL START_BYTE = 38 BYTES = 8 FORMAT = "F8.3" UNIT = KELVIN DESCRIPTION = "Middle mast thermocouple temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_MAST_BASE_ISO_BLOCK_PRT" DATA_TYPE = ASCII_REAL START_BYTE = 47 BYTES = 8 FORMAT = "F8.3" UNIT = KELVIN DESCRIPTION = "Mast base isothermal block platinum resistance thermometer temperature (PRT4), measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_DESCENT_THERMOCOUPLE" DATA_TYPE = ASCII_REAL START_BYTE = 56 BYTES = 8 FORMAT = "F8.3" UNIT = KELVIN DESCRIPTION = "Descent thermocouple temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_PRESSURE_TRANSDUCER_PRT" DATA_TYPE = ASCII_REAL START_BYTE = 65 BYTES = 8 FORMAT = "F8.3" UNIT = KELVIN DESCRIPTION = "Pressure sensor platinum resistance thermometer temperature (PRT5), measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_PRESSURE_TRANSDUCER_0_12" DATA_TYPE = ASCII_REAL START_BYTE = 74 BYTES = 8 FORMAT = "F8.4" UNIT = MILLIBAR DESCRIPTION = "Pressure (0-12 mbar range), measured in millibars." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_SEGMENT_1" DATA_TYPE = ASCII_REAL START_BYTE = 83 BYTES = 7 FORMAT = "F7.2" UNIT = KELVIN DESCRIPTION = "Wind sensor element 1 temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_SEGMENT_2" DATA_TYPE = ASCII_REAL START_BYTE = 91 BYTES = 7 FORMAT = "F7.2" UNIT = KELVIN DESCRIPTION = "Wind sensor element 2 temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_SEGMENT_3" DATA_TYPE = ASCII_REAL START_BYTE = 99 BYTES = 7 FORMAT = "F7.2" UNIT = KELVIN DESCRIPTION = "Wind sensor element 3 temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_SEGMENT_4" DATA_TYPE = ASCII_REAL START_BYTE = 107 BYTES = 7 FORMAT = "F7.2" UNIT = KELVIN DESCRIPTION = "Wind sensor element 4 temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_SEGMENT_5" DATA_TYPE = ASCII_REAL START_BYTE = 115 BYTES = 7 FORMAT = "F7.2" UNIT = KELVIN DESCRIPTION = "Wind sensor element 5 temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALIB_WIND_SENSOR_SEGMENT_6" DATA_TYPE = ASCII_REAL START_BYTE = 123 BYTES = 7 FORMAT = "F7.2" UNIT = KELVIN DESCRIPTION = "Wind sensor element 6 temperature, measured in degrees Kelvin." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_CURRENT" DATA_TYPE = ASCII_INTEGER START_BYTE = 131 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor current, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_MID_MAST_THERMOCOUPLE" DATA_TYPE = ASCII_INTEGER START_BYTE = 137 BYTES = 6 FORMAT = "I6" UNIT = DN DESCRIPTION = "Middle mast thermocouple temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_MAST_BASE_ISO_BLOCK_PRT" DATA_TYPE = ASCII_INTEGER START_BYTE = 144 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Mast base isothermal block platinum resistance thermometer temperature (PRT4), measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_DESCENT_THERMOCOUPLE" DATA_TYPE = ASCII_INTEGER START_BYTE = 150 BYTES = 4 FORMAT = "I4" UNIT = DN DESCRIPTION = "Descent thermocouple temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_PRESSURE_TRANSDUCER_PRT" DATA_TYPE = ASCII_INTEGER START_BYTE = 155 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Pressure sensor platinum resistance thermometer temperature (PRT5), measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_PRESSURE_TRANSDUCER_0_12" DATA_TYPE = ASCII_INTEGER START_BYTE = 161 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Pressure (0-12 mbar range), measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_SEGMENT_1" DATA_TYPE = ASCII_INTEGER START_BYTE = 167 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor element 1 temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_SEGMENT_2" DATA_TYPE = ASCII_INTEGER START_BYTE = 173 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor element 2 temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_SEGMENT_3" DATA_TYPE = ASCII_INTEGER START_BYTE = 179 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor element 3 temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_SEGMENT_4" DATA_TYPE = ASCII_INTEGER START_BYTE = 185 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor element 4 temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_SEGMENT_5" DATA_TYPE = ASCII_INTEGER START_BYTE = 191 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor element 5 temperature, measured in raw counts." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RAW_WIND_SENSOR_SEGMENT_6" DATA_TYPE = ASCII_INTEGER START_BYTE = 197 BYTES = 5 FORMAT = "I5" UNIT = DN DESCRIPTION = "Wind sensor element 6 temperature, measured in raw counts." END_OBJECT = COLUMN END_OBJECT = TABLE END