Data directory: 2014-01-10-07.32.28-36354-STS_exo_L2_2x5x10_v04_Rev395
Generated from Spacecraft Telemetry Files.
Original Comments:  GSE Comments: Data directory: NMS_SCIENCE/
CDH	FM	0	0.0
LSIM	FM	0	0.0
PS	FM	0	0.0
FB	FM	0	0.0
PROM Ver.	Jr
GSE:.	Revision: 1.0
Test temp.:.	Extremely mild
Note:	This file was created by ccsds2tm.
.packet 2
!
00000: LADEE NMS Flight Software Rev 2.3.4.0 Build 55 -- T. Nolan May  2 2013 14:54:51
00000: watchdog_task: initialized
00000: telem_task: initialized
00000: basic_task: initialized
00000: autoexec.bas $Revision: 100 $
00000: useq_task: AMUX table not found
00000: useq_task: initialized
00000: qms: loaded 150 mass table entries (old style) from file mt10811.dat
00000: qms: 7 bands loaded from file bt20111012a.dat
00000: qms: initialized
00000: qms: acquisition stopped
00000: alarm_task: 131 limit definitions loaded from file FlightLim1.4.dat.
00000: alarm_task: initialized
00000: hss_receiver: initialized
00000: hss_task: old time=0, new time=442611146
00002: lc: 131 channel entries, 131 enabled, 0 alarmed, alarm level=0
00002: Digital Status Interval Set To:	5
00002: qms.telem mode = 1
00002: malloc: 1245500 of 1310720 bytes allocated
00002: NMS is up!
00012: Loaded $Id: STS_exo_L2_2x5x10_v04.bas 395 2013-12-13 21:40:18Z lab $ $Revision: 395 $
00012: sys.marker: id=1, txt=<  STS_exo_L2_2x5x10_v04.bas
00012: Loaded SCI_main.bas $Revision: 351 $
00015: qms temperature compensation enabled
00015: SCI_main.bas $Revision: 351 $
00015: lc: 131 channel entries, 131 enabled, 0 alarmed, alarm level=0
00015: No Pressure Check
00015: qms.telem mode = 3
00015: qms: IP time=2470 setup=30
00016: Task Name: Level 1B
00016: qms: IP time=2470 setup=30
00016: sys.marker: id=2, txt=    < restore STS_SCRIPT
00016: sys.marker: id=3, txt=    < Level 1B
00019: Task Name: Electronic Background
00022: qms: IP time=270 setup=30
00023: sys.marker: id=4, txt=    < CS_FIL_ON
00023: sys.marker: id=5, txt= > BCO-FIL-t995-f2-m2-v2800-e200-i30 47
00047: qms: IP time=2470 setup=30
00048: sys.marker: id=6, txt= > BCO-TBL-t1005-f2-m2-v2800-e200-i250
00048: Task Name: He, Ne, Ar 5x10 peak-top
00049: ScanTableFunction: Command = -2 ScnVecReps deaulting to max
00054: sys.marker: id=7, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00174: sys.marker: id=8, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00294: sys.marker: id=9, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00414: sys.marker: id=10, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00534: sys.marker: id=11, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00654: sys.marker: id=12, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00774: sys.marker: id=13, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
00894: sys.marker: id=14, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01014: sys.marker: id=15, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01134: sys.marker: id=16, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01254: sys.marker: id=17, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01374: sys.marker: id=18, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01494: sys.marker: id=19, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01613: sys.marker: id=20, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01733: sys.marker: id=21, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01853: sys.marker: id=22, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
01973: sys.marker: id=23, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02093: sys.marker: id=24, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02213: sys.marker: id=25, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02333: sys.marker: id=26, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02453: sys.marker: id=27, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02573: sys.marker: id=28, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02693: sys.marker: id=29, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02813: sys.marker: id=30, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
02933: sys.marker: id=31, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
03053: sys.marker: id=32, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
03173: sys.marker: id=33, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250
03293: sys.marker: id=34, txt= > CSN-TBL-t1019-f2-m2-v2800-e200-i250