<?xml version='1.0' encoding='UTF-8'?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<?xml-model href="https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Context xmlns="http://pds.nasa.gov/pds4/pds/v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ctli="http://pds.nasa.gov/pds4/ctli/v2" xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.xsd http://pds.nasa.gov/pds4/ctli/v2 https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.xsd">
  <Identification_Area>
    <logical_identifier>urn:nasa:pds:context:instrument:eso-la_silla.3m6.timmi2</logical_identifier>
    <version_id>1.4</version_id>
    <title>Thermal Infrared Multi-Mode Instrument 2</title>
    <information_model_version>1.25.0.0</information_model_version>
    <product_class>Product_Context</product_class>
    <Alias_List>
      <Alias>
        <alternate_title>urn:nasa:pds:context:instrument:eso.3m6.timmi2</alternate_title>
      </Alias>
      <!-- deprecated LID -->
    </Alias_List>
    <Modification_History>
      <Modification_Detail>
        <modification_date>2026-07-07</modification_date>
        <version_id>1.4</version_id>
        <description>Removed duplicate Internal_Reference entries from Reference_List.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-12-24</modification_date>
        <version_id>1.3</version_id>
        <description>Adding missing "facility" references. Adding missing "telescope" references.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-12-24</modification_date>
        <version_id>1.2</version_id>
        <description>Updated schema version. Adding missing "facility" references. Adding missing "telescope" references.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-01-02</modification_date>
        <version_id>1.1</version_id>
        <description>Updated schema version. Adding missing "telescope" references.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2021-12-07</modification_date>
        <version_id>1.0</version_id>
        <description>per RMS, deprecated eso in favor of eso-la_silla</description>
      </Modification_Detail>
    </Modification_History>
  </Identification_Area>
  <Reference_List>
    <Internal_Reference>
      <lid_reference>urn:nasa:pds:context:telescope:eso-la_silla.3m6</lid_reference>
      <reference_type>instrument_to_telescope</reference_type>
    </Internal_Reference>
    <Internal_Reference>
      <lid_reference>urn:nasa:pds:context:facility:observatory.eso-la_silla</lid_reference>
      <reference_type>instrument_to_facility</reference_type>
    </Internal_Reference>
    <External_Reference>
      <reference_text>Reimann, H.G., E. Dietzsch, J. Hron et al., TIMMI2: A new multimode mid-infrared
instrument for the ESO 3.6m telescope, Proceedings of SPIE, Vol. 4008, p. 131, 2000.</reference_text>
    </External_Reference>
  </Reference_List>
  <Instrument>
    <name>Thermal Infrared Multi-Mode Instrument 2</name>
    <Type_List_Area>
      <ctli:Type_List>
        <ctli:type>Imager</ctli:type>
      </ctli:Type_List>
    </Type_List_Area>
    <description>TIMMI2 is a multi mode (imaging, polarimetry, and long slit spectroscopy) thermal-infrared (4-20 um) instrument working at the ESO/3.6m Cassegrain, f/35 focus. Lenses offering different magnifications are available in the different bands: 0.3 arcsec/pixel in the L and M bands; 0.2 arcsec/pixel and 0.3 arcsec/pixel in the N band; and 0.2 arcsec/pixel in the Q band.  The array is a Si:As chip manufactured by Raytheon, with format 320 x 240 pixels (the pixel size is 50 microns), distributed in 16 channels of 20 columns each. So the field sizes are 64x48 arcsecs or 96x72 arcsecs for the small and large field lenses, respectively. It's sensitive from 2 to 28 microns, with a mean QE of 31.6 percent, a read noise of 922e-, a full well capacity of 1.13x107/2.04x107e- (high/low gain), and a dark current &lt; 100e-/sec at T=6K.         </description>
  </Instrument>
</Product_Context>
