<?xml version='1.0' encoding='UTF-8'?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<?xml-model href="https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Context xmlns="http://pds.nasa.gov/pds4/pds/v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ctli="http://pds.nasa.gov/pds4/ctli/v2" xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.xsd http://pds.nasa.gov/pds4/ctli/v2 https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.xsd">
  <Identification_Area>
    <logical_identifier>urn:nasa:pds:context:instrument:orm.galileo_zeiss3m5.dolores</logical_identifier>
    <version_id>1.3</version_id>
    <title>DOLORES (Device Optimized for LOw RESolution)</title>
    <information_model_version>1.25.0.0</information_model_version>
    <product_class>Product_Context</product_class>
    <Modification_History>
      <Modification_Detail>
        <modification_date>2026-07-07</modification_date>
        <version_id>1.3</version_id>
        <description>Removed duplicate Internal_Reference entries from Reference_List.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-12-24</modification_date>
        <version_id>1.2</version_id>
        <description>Updated schema version. Adding missing "telescope" references.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-01-02</modification_date>
        <version_id>1.1</version_id>
        <description>Updated schema version. Update instrument type/subtype to use valid CTLI LDD.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2020-02-18</modification_date>
        <version_id>1.0</version_id>
        <description>Initial export from OLAF</description>
      </Modification_Detail>
    </Modification_History>
  </Identification_Area>
  <Reference_List>
    <Internal_Reference>
      <lid_reference>urn:nasa:pds:context:telescope:orm.galileo_zeiss3m5</lid_reference>
      <reference_type>instrument_to_telescope</reference_type>
    </Internal_Reference>
  </Reference_List>
  <Instrument>
    <name>DOLORES (Device Optimized for LOw RESolution)</name>
    <Type_List_Area>
      <ctli:Type_List_Set>
        <ctli:Type_List>
          <ctli:type>Imager</ctli:type>
        </ctli:Type_List>
        <ctli:Type_List>
          <ctli:type>Spectrometer</ctli:type>
        </ctli:Type_List>
      </ctli:Type_List_Set>
    </Type_List_Area>
    <description>DOLORES (Device Optimized for LOw RESolution) is a focal reducer instrument installed at the Nasmyth B focus of the Telescopio Nazionale Galileo at La Palma. The detector is a 2048 x 2048 E2V 4240 thinned back-illuminated, deep-depleted, Astro-BB coated CCD with a pixel size of 13.5 microns. The scale is 0.252 arcsec/pixel which yields a field of view of about  8.6 x 8.6 arcmin. The instrument allows imaging through broad and narrow band filters as well as spectroscopic observations with resolving powers between RS = ~500 and RS = ~6000. A multi-slit mode, based on custom masks manufactured by a dedicate cutting machine, is also available.  Grisms:  Name    disp.   wavelength range (A)    Resolution         A/Pix   min     central max     (1" slit)  LR-B    2.52    3000    5850    8430    585 LR-R    2.61    4470    7400    10073   714 V390    0.26    3634    3900    4166    3766 V486    0.20    4612    4725    4838    5953 V510    0.22    4875    5100    5325    5950 V589    0.27    5619    5895    6171    5502 V656    0.32    6232    6560    6888    5248 V860    0.44    8149    8600    9051    4000 VHRV    0.95    4752    5725    6698    1527 VHRR    0.70    6238    7000    7717    2513 VHRI    0.68    7433    8130    8826    3035  Notes:  1.  The LR-R Grism has a built-in order-blocking filter cutting blueward ~5000 angstroms; nevertheless, blue objects will show noticeable second-order overlap above ~9500 angstroms. 2.  The V390 Grism is not mounted on the grism wheel and may be used ONLY in visitor mode. Users interested in using this grism must explicitly request it in the Observing Proposal. 3.  The V860, VHRR, and VHRI Grisms suffer from significant second-order effect and will be automatically coupled  with the ~560 nm cut-on filter available on the filters wheel. 4.  Resolution calculated for a 1" Slit. 5.  Please note that there aren't suitable wavelength calibration lamps for the V486 GRISM.</description>
  </Instrument>
</Product_Context>
