<?xml version='1.0' encoding='UTF-8'?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<?xml-model href="https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Context xmlns="http://pds.nasa.gov/pds4/pds/v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ctli="http://pds.nasa.gov/pds4/ctli/v2" xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.xsd http://pds.nasa.gov/pds4/ctli/v2 https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.xsd">
  <Identification_Area>
    <logical_identifier>urn:nasa:pds:context:instrument:utsa_kamc.bruker_eds</logical_identifier>
    <version_id>1.3</version_id>
    <title>University of Texas at San Antonio Kleberg Advanced Microscopy Center Bruker Quantax XFlash 4010 SSD Energy-Dispersive X-Ray Detector</title>
    <information_model_version>1.25.0.0</information_model_version>
    <product_class>Product_Context</product_class>
    <Alias_List>
      <Alias>
        <alternate_title>Bruker XFlash 4010 SSD energy-dispersive X-ray detector (EDS)</alternate_title>
      </Alias>
    </Alias_List>
    <Modification_History>
      <Modification_Detail>
        <modification_date>2026-07-07</modification_date>
        <version_id>1.3</version_id>
        <description>Removed duplicate Internal_Reference entries from Reference_List.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-12-24</modification_date>
        <version_id>1.2</version_id>
        <description>Updated schema version. Removed instrument_to_investigation references. Adding missing "facility" references.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2025-01-02</modification_date>
        <version_id>1.1</version_id>
        <description>Updated schema version. Adding missing "investigation" references. Adding missing "facility" references.</description>
      </Modification_Detail>
      <Modification_Detail>
        <modification_date>2024-04-23</modification_date>
        <version_id>1.0</version_id>
        <description>
                    Initial version. 
                </description>
      </Modification_Detail>
    </Modification_History>
  </Identification_Area>
  <Reference_List>
    <Internal_Reference>
      <lid_reference>urn:nasa:pds:context:facility:laboratory.utsa_kamc</lid_reference>
      <reference_type>instrument_to_facility</reference_type>
    </Internal_Reference>
  </Reference_List>
  <Instrument>
    <name>University of Texas at San Antonio Kleberg Advanced Microscopy Center Bruker Quantax XFlash 4010 SSD Energy-Dispersive X-Ray Detector</name>
    <Type_List_Area>
      <ctli:Type_List>
        <ctli:type>Spectrometer</ctli:type>
        <ctli:subtype>Energy Dispersive X-ray Detector</ctli:subtype>
      </ctli:Type_List>
    </Type_List_Area>
    <description>The Bruker Quantax XFlash 4010 SSD EDX detector is an attachment for the Hitachi S5500 Field-Emission SEM, which enables the chemical analysis of both thin and bulk sample areas. This detector allows for energy-dispersive X-ray (EDX) spectroscopy of samples excited by the SEM electron beam. The energy of the x-ray emissions from the excited sample is unique to different elements and the intensity of the emission lines is converted to abundance using the interactive oxide quantification algorithm in the Bruker ESPRIT            software, following background subtraction and peak deconvolution. Available EDX modes are line scanning and 2D mapping. The instrumentation is located at the University of Texas at San Antonio's Kleberg Advanced Microscopy Center.   </description>
  </Instrument>
</Product_Context>