<?xml version='1.0' encoding='UTF-8'?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<?xml-model href="https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Context xmlns="http://pds.nasa.gov/pds4/pds/v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ctli="http://pds.nasa.gov/pds4/ctli/v2" xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1P00.xsd http://pds.nasa.gov/pds4/ctli/v2 https://pds.nasa.gov/pds4/ctli/v2/PDS4_CTLI_1P00_2300.xsd">
  <Identification_Area>
    <logical_identifier>urn:nasa:pds:context:instrument:arc-ocf.thermo-fisher_is50-ftir-spec</logical_identifier>
    <version_id>1.0</version_id>
    <title>Thermo Fisher iS50 FTIR Spectrometer</title>
    <information_model_version>1.25.0.0</information_model_version>
    <product_class>Product_Context</product_class>
    <Modification_History>
      <Modification_Detail>
        <modification_date>2026-04-14</modification_date>
        <version_id>1.0</version_id>
        <description>
                    Initial creation of the context product. 
                </description>
      </Modification_Detail>
    </Modification_History>
  </Identification_Area>
  <Reference_List>
    <Internal_Reference>
      <lid_reference>urn:nasa:pds:context:facility:laboratory.arc-ocf</lid_reference>
      <reference_type>instrument_to_facility</reference_type>
    </Internal_Reference>
  </Reference_List>
  <Instrument>
    <name>Thermo Fisher iS50 FTIR Spectrometer</name>
    <Type_List_Area>
      <ctli:Type_List>
        <ctli:type>Spectrometer</ctli:type>
        <ctli:subtype>Visible</ctli:subtype>
        <ctli:subtype>Near-Infrared</ctli:subtype>
        <ctli:subtype>Infrared</ctli:subtype>
        <ctli:subtype>Far-Infrared</ctli:subtype>
      </ctli:Type_List>
    </Type_List_Area>
    <description>The Thermo Fisher iS50 FTIR spectrometer allows spectroscopic characterization of the spectral properties of samples from 
      0.6 to 200 µm (17,000–50 cm–1). This wide wavelength range is made possible by the availability of four different detectors [Si (visible, 
      Vis), TEC-InGaAs (near infrared, NIR), DLaTGS-KBr (mid-infrared, MIR), DLaTGS-Polyethylene (far infrared, FIR)] and  four different 
      beamsplitters [Quartz (Vis), CaF2 (NIR), KBr (MIR), Solid Substrate (FIR)]. An automated exchanger allows full spectral coverage without 
      breaking purge. The spectra can be measured with a resolution as low as 0.5 cm-1. Two Harrick Scientific accessories, the Variable Angle 
      Transmission Accessory (VATA) and the SEAGULL variable angle reflectance accessory, can be coupled to the FTIR spectrometer to allow the 
      characterization of the optical properties of solid samples, over a broad range of incidence and emittance angles, from 0° to 90° for the 
      VATA accessory, and from 5° to 85° for the SEAGULL accessory. The VATA and SEAGULL accessories enable the characterization of the angular 
      light distribution in both transmission and reflection measurements.</description>
  </Instrument>
</Product_Context>