<?xml version="1.0" encoding="UTF-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1G00.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<?xml-model href="https://pds.nasa.gov/pds4/ctli/v1/PDS4_CTLI_1G00_1200.sch" schematypens="http://purl.oclc.org/dsdl/schematron"
?>
<Product_Context xmlns="http://pds.nasa.gov/pds4/pds/v1"
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xmlns:ctli="http://pds.nasa.gov/pds4/ctli/v1"
    xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1G00.xsd
    http://pds.nasa.gov/pds4/ctli/v1 https://pds.nasa.gov/pds4/ctli/v1/PDS4_CTLI_1G00_1200.xsd">
    
    <Identification_Area>
        <logical_identifier>urn:nasa:pds:context:instrument:pgl.asd-fieldspec3</logical_identifier>
        <version_id>1.0</version_id>
        <title>Analytical Spectral Devices FieldSpec 3</title>
        <information_model_version>1.16.0.0</information_model_version>
        <product_class>Product_Context</product_class>
        <Modification_History>
            <Modification_Detail>
                <modification_date>2023-08-28</modification_date>
                <version_id>1.0</version_id>
                <description>
                    Initial version. 
                </description>
            </Modification_Detail>
        </Modification_History>
    </Identification_Area>    
    <Reference_List>
        <Internal_Reference>
            <lid_reference>urn:nasa:pds:context:facility:laboratory.pgl</lid_reference>
            <reference_type>instrument_to_facility</reference_type>
        </Internal_Reference>
    </Reference_List>    
    <Instrument>
        <name>Analytical Spectral Devices FieldSpec 3</name>
        <Type_List_Area>
            <ctli:Type_List>
                <ctli:type>Spectrometer</ctli:type>
                <ctli:subtype>VNIR</ctli:subtype>
            </ctli:Type_List>
        </Type_List_Area>
        <description>
            Analytical Spectral Devices FieldSpec 3 
            https://www.malvernpanalytical.com/en/products/product-range/asd-range/fieldspec-range 
            {website only has info for upgraded FieldSpec 4}
            
            Manual for FieldSpec 3 available at
            http://www.geo-informatie.nl/courses/grs60312/material2017/manuals/600540-JFieldSpec3UserManual.pdf
            
            The 0.35-2.5 um range was acquired at ambient room temperature and pressure with an Analytical Spectral Devices 
            FieldSpec 3 with fiber optic cable bundle. Spectral resolution was 3 nm FWHM in the 0.35-1.0 um range and 10 nm 
            FWHM resolution from 1.0-2.5 um. Geometry (biconical) of the measurements was an incidence of 0º and emission 
            angle of 30º, for a phase angle of 30º. Illumination was provided by a bare quartz halogen full spectrum bulb 
            40 cm above the sample. Measurements were taken relative to a flat Spectralon standard that was positioned at 
            the same height as the sample.           
        </description>
    </Instrument>
</Product_Context>