OBJECT = COLUMN NAME = 'UT' COLUMN_NUMBER = 1 UNIT = 'SEC' DATA_TYPE = 'FLOAT' START_BYTE = 1 BYTES = 8 DESCRIPTION = "UT: Universal Time given in seconds since 1966-01-01T00:00:00.000 where no attempt has been made to account for leap seconds. The time stamp corresponds to the center time of a two spin period averaging window." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E100HZMX' COLUMN_NUMBER = 2 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 9 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Maximum wave amplitude per root Hertz per 24 second interval, measured at 100 Hz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E100HZAV' COLUMN_NUMBER = 3 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 13 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Average wave amplitude per root Hertz per 24 second interval, measured at 100 Hz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E100HZMN' COLUMN_NUMBER = 4 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 17 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Minimum wave amplitude per root Hertz per 24 second interval, measured at 100 Hz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E730HZMX' COLUMN_NUMBER = 5 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 21 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Maximum wave amplitude per root Hertz per 24 second interval, measured at 730 Hz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E730HZAV' COLUMN_NUMBER = 6 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 25 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Average wave amplitude per root Hertz per 24 second interval, measured at 730 Hz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E730HZMN' COLUMN_NUMBER = 7 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 29 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Minimum wave amplitude per root Hertz per 24 second interval, measured at 730 Hz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E5.4KHZMX' COLUMN_NUMBER = 8 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 33 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Maximum wave amplitude per root Hertz per 24 second interval, measured at 5.4 kHz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E5.4KHZAV' COLUMN_NUMBER = 9 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 37 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Average wave amplitude per root Hertz per 24 second interval, measured at 5.4 kHz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E5.4KHZMN' COLUMN_NUMBER = 10 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 41 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Minimum wave amplitude per root Hertz per 24 second interval, measured at 5.4 kHz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E30KHZMX' COLUMN_NUMBER = 11 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 45 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Maximum wave amplitude per root Hertz per 24 second interval, measured at 30 kHz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E30KHZAV' COLUMN_NUMBER = 12 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 49 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Average wave amplitude per root Hertz per 24 second interval, measured at 30 kHz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN OBJECT = COLUMN NAME = 'E30KHZMN' COLUMN_NUMBER = 13 UNIT = 'V/M/HZ.5' DATA_TYPE = 'FLOAT' START_BYTE = 53 BYTES = 4 MISSING = 1.000000E+32 DESCRIPTION = "Minimum wave amplitude per root Hertz per 24 second interval, measured at 30 kHz. At a particular frequency the wave electric field amplitude (V/M) is measured over the bandwidth of the filter (30% for OEFD). The square root of the bandwidth is incorporated in order to compare measurements made with this instrument with other wave measurements, which may have different bandwidths." END_OBJECT = COLUMN