Name: heater_control_mode | Version Id: 1.0.0.0 | ||
---|---|---|---|
Description: The heater_control_mode attribute provides the state of the HiRISE heater control, either closed-loop or duty-cycle. Normally the closed-loop mode is used to keep nominal operating temperatures of the instrument. A duty-cycle mode is enabled during periods of high EM emissions from other MRO instruments. | |||
Namespace Id: mro | Steward: geo | Class Name: HiRISE_Instrument_Setting_Parameters | Type: ASCII_Short_String_Collapsed |
Minimum Value: None | Maximum Value: None | Minimum Characters: 1 | Maximum Characters: 255 |
Unit of Measure Type: None | Default Unit Id: None | Attribute Concept: None | Conceptual Domain: SHORT_STRING |
Status: Active | Nillable: false | Pattern: None | |
Permissible Value(s) | Value | Value Meaning | |
CLOSED LOOP | closed-loop mode | ||
DUTY CYCLE | duty cycle mode |