fw_pos in MDIS

Name: fw_posVersion Id: 1.0.0.0
Description: The actual position, in raw counts of the position resolver on the MDIS filter wheel. For each commanded filter number, the instrument software will try to place the filter wheel at the following positions: FILTER_NUMBER mess.mdis.fw_goal 1 17376 2 11976 3 6492 4 1108 5 61104 6 55684 7 50148 8 44760 9 39256 10 33796 11 28252 12 22852 Commanded position is reported in mess.mdis.fw_goal. There is a tolerance of 240 resolver counts around mess.mdis.fw_goal for mess.mdis.fw_pos to indicate that the filter wheel is correctly positioned.
Namespace Id: messSteward: ppiClass Name: MDISType: ASCII_​Integer
Minimum Value: 0Maximum Value: 65535Minimum Characters: NoneMaximum Characters: None
Unit of Measure Type: NoneDefault Unit Id: NoneAttribute Concept: NoneConceptual Domain: INTEGER
Status: ActiveNillable: falsePattern: None
Permissible Value(s)No Values