piv_read in MDIS

Name: piv_readVersion Id: 1.0.0.0
Description: Raw pivot reading from resolver (in units of resolver counts). The pivot platform resolver only covers 45 degrees of motion; the resolver read-out values repeat eight times over the entire 360 degrees that an unconstrained platform could travel. This value is used along with dead-reckoning knowledge of which octant the platform is in to give the value in mess.mdis.piv_pos.
Namespace Id: messSteward: ppiClass Name: MDISType: ASCII_​Integer
Minimum Value: 0Maximum Value: 65535Minimum Characters: NoneMaximum Characters: None
Unit of Measure Type: NoneDefault Unit Id: NoneAttribute Concept: NoneConceptual Domain: INTEGER
Status: ActiveNillable: falsePattern: None
Permissible Value(s)No Values