Name: gain | Version Id: 1.0.0.0 | ||
---|---|---|---|
Description: The sensor analog gain value to use. Legal values are 8-31 and 40-63. Values from 8 to 31 specify gains in the range 1 to 3.875 in steps of 0.125; values from 40 to 63 specify gain in the range 2 to 7.75 in steps of 0.25. Gains in the range [2, 4) should be commanded using the first range | |||
Namespace Id: orex | Steward: sbn | Class Name: TAGCAMS_Instrument_Attributes | Type: ASCII_Real |
Minimum Value: -1.7976931348623157e308 | Maximum Value: 1.7976931348623157e308 | Minimum Characters: None | Maximum Characters: None |
Unit of Measure Type: None | Default Unit Id: None | Attribute Concept: None | Conceptual Domain: REAL |
Status: Active | Nillable: false | Pattern: None | |
Permissible Value(s) | No Values |